Fluke 1621 GEO Earth Ground Tester
Reliable Ground Testing with Professional Precision
Product Overview
Fluke 1621 GEO Earth Ground Tester Price in Bangladesh
Fluke 1621 GEO Earth Ground Tester Price in Bangladesh is a professional grade earth resistance testing instrument designed for accurate and reliable grounding measurements in electrical and industrial systems. Fluke 1621 GEO Earth Ground Tester Price in Bangladesh is widely used by engineers, technicians, and maintenance professionals who require dependable performance in field and industrial environments.
This advanced earth ground tester is engineered to deliver precise results for grounding system verification, helping ensure electrical safety and system stability. It supports both 2 pole and 3 pole testing methods, allowing users to perform flexible and efficient ground resistance measurements based on application requirements.
Built with durable construction, the device is suitable for tough working conditions and long term field use. Its user friendly interface allows smooth operation, making it easy for professionals to perform tests quickly and accurately without unnecessary complexity.
The tester provides stable readings and consistent performance, which is essential for identifying grounding issues and maintaining safe electrical installations. It is designed to support preventive maintenance tasks, helping reduce system failures and improving overall electrical safety standards.
With its reliable measurement capability, the device is ideal for use in power systems, industrial plants, electrical maintenance services, and construction projects. It ensures that grounding systems are properly functioning, which is critical for protecting both equipment and human safety.
Overall, this earth ground tester is a trusted solution for professionals who need accuracy, durability, and efficiency in grounding resistance testing applications.
Key Features:Fluke 1621 GEO Earth Ground Tester
- Easily capture values with single-button operation
- 3-pole Fall-of-Potential earth testing for basic measurements
- 2-pole resistance measurements for added versatility
- Ensure accurate measurements with automatic ‘noise’ voltage detection
- Hazardous voltage warning offers increased user protection
- Clearly read and record data with a large, backlit display
- Rugged holster and design for tough work environments
- Portable size allows for easy transportation
- Instantly be alerted to measurements outside of your set limit, when you use the adjustable limit setting
- 600 V Cat II
Specifications
Specifications: Fluke 1621 GEO Earth Ground Tester
| General Specifications | ||
| Measuring functions | 3-pole earth ground resistance, 2-pole ac resistance of a conductor, Interference voltage | |
| Intrinsic error | Refers to the reference temperature range and is guaranteed for one year | |
| Measuring rate | 2 measurements/second | |
| Battery1 | One 9 volt alkaline (LR61) | |
| Battery condition | LO-BAT is displayed if voltage drops below 6.5 V | |
| Voltages | Between jacks H/C2 and E/C1 | 250 Veff maximum (effective voltage) |
| Between jacks S/P2 and E/C1 | 250 Veff maximum | |
| Climatic class | VDE/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4/87) | |
| Temperature performance2 | Working | -10°C to +50°C (+14°F to +122°F) |
| Operating | 0°C to +35°C (+32°F to +95°F) | |
| Storage | -20°C to +60°C (+68°F to +140°F) | |
| Reference | +23°C ±2°C (+73°F ±4°F) | |
| Temperature coefficient | ±0.1% of range per degree Kelvin | |
| Safety | IEC/EN 61010-1, 600 V CAT II, pollution degree 2 | |
| Dimensions | 113 x 54 x 216 mm (4.5 x 2.1 x 8.5 in), including holster | |
| Weight | 850 g (1.9 lb), including standard accessories, volume approximately 600 cm3 | |
| Electrical Specifications | ||
| Maximum deviations | E1 Influence factor | Position |
| E1 Deviation influence | 0% | |
| E2 Influence factor | Supply voltage | |
| E2 Deviation influence | 0% | |
| E3 Influence factor | Temperature E3 | |
| E3 Deviation influence | 2.3% | |
| E4 Influence factor | Serial interference voltage (20 V) | |
| E4 Deviation influence | 0.6% | |
| E5 Influence factor | Probe- and auxiliary probe resistance | |
| E5 Deviation influence | 10% | |
| Test voltage | 3.7 kV | |
| Protection type | IP 40; IEC/EN 60529 | |
| Electromagnetic compatibility | Emission | IEC/EN 61326 Class B |
| Immunity | IEC/EN 61326 Annex C | |
| RE Resistance measurement | Measuring method | Current-voltage measurement with improved cross-talk attenuation, no compensation of measuring lead resistance, with probe (3-pole) or without probe (2-pole), as per IEC/EN 61557–5 |
| Open circuit voltage | 23 to 24 V AC | |
| Short circuit current | > 50 mA AC | |
| Measuring frequency | 128 Hz | |
| Maximum permissible overload | 250 Veff | |
| Measuring time | 8 seconds (average from when START is pressed) | |
| Limit input | Tester retains set value even if instrument is turned off (assuming battery power supply is sufficient) | |
| Automatic changeover of resolution | RH | < 7 kΩ |
| Resolution | 0.01 Ω | |
| RH | < 50 kΩ | |
| Resolution | 0.1 Ω | |
| RH | > 50 kΩ | |
| Resolution | 1 Ω | |
| Interference voltage display DC + AC | Vmax | 30 Veff |
| Common mode rejection | > 80 dB at 50 Hz and 60 Hz | |
| Ri | 680 kΩ | |
| Measuring uncertainty | < 10% for pure AC and DC signals | |
| Measuring Range | ||
| 0.15 Ω to 20 Ω | Resolution | 0.01 Ω |
| Display range | 0 to 19.99 Ω | |
| 200 Ω | Resolution | 0.1 Ω |
| Display range | 20 to 199.9 Ω | |
| 2 kΩ | Resolution | 1 Ω |
| Display range | 200 to 1999 Ω | |
| Intrinsic Uncertainty | ±(6% of measured value + 5D) | |
| Operating uncertainty IEC 615573 | ±(18% of measured value + 5D) | |
| 1. If the tester is not going to be used, or is being stored for a long period, remove the battery and store separately from the tester to avoid damage from battery leakage. 2. The four temperature ranges for the tester exists to satisfy European Standards requirements; the instrument can be used over the full working temperature range by using the temperature coefficient to calculate accuracy at the ambient temperature of use. 3. Covers all deviations caused by influence quantities E1–E5. If the deviation E4 caused by high probe or auxiliary probe resistance is higher than specified flashes. Measured values are outside of the specified operating uncertainty. |
||