Hioki Rm3545a Resistance Meter

Hioki Rm3545a Resistance Meter

Hioki Rm3545a Resistance Meter

Ultra precision resistance measurement for industrial excellence

Product Overview

Hioki Rm3545a Resistance Meter Price in Bangladesh

Hioki RM3545A Resistance Meter is a high end precision measurement instrument designed for advanced industrial and research applications, and the Hioki RM3545A Resistance Meter Price in Bangladesh is typically searched by engineers and quality control professionals who require extremely accurate low resistance testing solutions. This device is widely used in EV manufacturing, motor testing, transformer analysis, and electronic component evaluation.

Built with ultra high precision technology, the RM3545A delivers exceptional accuracy in low resistance measurement, making it suitable for detecting even the smallest variations in electrical paths. It supports four terminal measurement methods to eliminate errors caused by lead resistance, ensuring highly stable and reliable results. The instrument is designed for both laboratory and production line environments where measurement accuracy is critical.

The device offers a wide measurement range and high speed testing capability, allowing users to perform fast and efficient resistance checks without compromising accuracy. It also includes advanced functions such as comparator settings, temperature compensation, and data analysis features that help improve quality control processes in industrial applications. These features make it highly effective for modern manufacturing environments where precision and efficiency are essential.

One of the key strengths of the RM3545A is its ability to integrate into automated testing systems. It supports multi channel expansion options, enabling simultaneous measurements across multiple points. This makes it ideal for large scale production testing, especially in EV battery systems and complex electrical assemblies where multiple resistance points must be monitored.

The device is designed with a clear digital interface that provides easy readability of measurement data. Its user friendly operation allows engineers to configure tests quickly and efficiently, reducing setup time during critical testing processes. The built in communication interfaces also support data transfer and remote control, enhancing workflow automation and digital reporting capabilities.

Durability and long term reliability are key aspects of this instrument. It is engineered for continuous industrial use, ensuring stable performance even in demanding environments. The robust construction and high quality internal components make it suitable for long term operation in factories, laboratories, and testing facilities.

Overall, this resistance meter stands out for its ultra precise measurement capability, advanced functionality, and industrial grade reliability. It is an essential tool for professionals who require accurate and consistent resistance measurement in high performance engineering and production environments.

Key Features: Hioki Rm3545a Resistance Meter

  • 0.045% basic accuracy, 1 nΩ max. resolution, 1A max. testing current
  • Measure from 1 nΩ (testing current 1 A) to 1200 MΩ
  • Equipped with advanced features, ensuring precise resistance measurement (OVC, temperature measurement, and correction function)
  • The RM3545A-2 can be equipped with up to two optional Z3003 Multiplexer Units, allowing it to measure up to 20 channels (using the 4-terminal method)
  • High path resistance tolerance allows seamless integration into an automatic test system, eliminating concerns about wiring or contact resistance
  • Advanced contact-check, comparator function, control, and co
Specifications

Basic specifications: Hioki Rm3545a Resistance Meter Price in Bangladesh

Accuracy guaranteed: 1 year

Resistance range (13 ranges) [Range, Maximum display value, Resolutions, Testing current (Measurement current) ]
1000 μΩ: 1200.000 μΩ, 1 nΩ, 1 A
10 mΩ: 12.000 00 mΩ, 10 nΩ, 1 A
100 mΩ: 120.000 0 mΩ, 100 nΩ, 1 A
1000 mΩ: 1200.000 mΩ, 1 μΩ, 100 mA
10 Ω: 12.000 00 Ω, 10 μΩ, 10 mA
100 Ω: 120.000 0 Ω, 100 μΩ, 10 mA
1000 Ω: 1200.000 Ω, 1 mΩ, 1 mA
10 kΩ: 12.000 00 kΩ, 10 mΩ, 1 mA
100 kΩ: 120.000 0 kΩ, 100 mΩ, 100 μA
1000 kΩ: 1200.000 kΩ, 1 Ω, 10 μA
10 MΩ 12.000 00 MΩ, 10 Ω, 1 μA
100 MΩ (100 MΩ range high-precision mode): 120.000 0 MΩ, 100 Ω, 100 nA
1000 MΩ: 1200.0 MΩ, 100 kΩ, 1 μA or less
Representative accuracy (High mode, OVC function enabled, SLOW2, no zero adjustment) 1000 μΩ range: ±0.045% rdg ±0.010 % f.s.
10 mΩ range: ±0.045% rdg ±0.001 % f.s.
100 mΩ range: ±0.045% rdg ±0.001 % f.s.
1000 mΩ range: ±0.012% rdg ±0.001 % f.s.
1000 Ω range: ±0.006% rdg ±0.001 % f.s.
Testing current (Measurement current) High mode: 1000μΩ (1 A) to 1000 MΩ (up to 1 μA)
Low mode: 100 mΩ (100 mA) to 100 Ω (1 mA)
Low power mode (LP): Low power measurement with measurement current and open circuit voltage down to 20 mV
LP1000 mΩ (1 mA) to LP1000 Ω (5 μA)
Measurement speed Representative value: FAST (2.3 ms) / MED (50 Hz: 22 ms, 60 Hz: 19 ms) / SLOW1 (102 ms) / SLOW2 (202 ms)
PR10 mΩ range*: FAST (21 ms) / MED (50 Hz: 41 ms, 60 Hz: 37 ms) / SLOW1 (121 ms) / SLOW2 (221 ms)
Path resistance tolerance (reference values)
Path resistance between SOURCE B and SOURCE A (other than measurement target)
Range: 100 mΩ or less (PR* mode off) : 2.6 Ω
Range: 100 mΩ or less (PR* mode on) : 3.5 Ω
Range: 1000 mΩ: 15 Ω
Range: 10 Ω : 150 Ω
Range: 100 Ω : 100 Ω
Range: 10 kΩ : 500 Ω
Range: 100 kΩ or greater: 1 kΩ
Maximum open-terminal voltage Range: 1000 Ω or less: 8.0 V
Range: 10 kΩ or greater: 20 V
Temperature measurement Temperature Sensor (Z2001[included accessories]): -10.0℃ to 99.9℃
Analog input (Ex: Infrared thermometer): DC 0 V to 2.0 V
Multiplexer (built-in option)*
*RM3545A-2 only
Multiplexer unit Z3003
Number of installable units:Max. 2
Maximum number of channels : 20 channels (4-wire method), 42 channels (2-wire method)
Switching time : 30 ms
Multiplexer (external option) Switch Mainframe
Maximum number of channels (SW1001): 33 channels (4-wire method)
Maximum number of channels (SW1002): 132 channels (4-wire method)
Switching time:11 ms
Communication interfaces LAN (TCP/IP, 10BASE-T/100BASE-TX), RS-232C (Max. 115200 bps, also used as printer interface), USB, EXT I/O (D-sub 37-pin, Analog output (D/A output voltage range: DC 0 V to 1.5 V )
Functions Contact check, Zero adjustment (within each range ±50% f.s.) *1, Zero-adjustment-free accuracy guaranteed, OVC function, Contact improvement function (max. applied voltage: 5V; max. applied current: 10 mA), Low-power mode (maximum open voltage: 20 mV), Auto-hold function, Comparator, Temperature measurement function, Temperature correction (TC) function, Temperature conversion (ΔT) function, Statistical calculation function, Delay function, Averaging function, Saving panels (saving of measurement conditions), Data memory function, Command monitor function (display of send/receive status of commands and queries),LabVIEW® Driver compatible*2
*1: Zero adjustment forcibly disabled for 100 MΩ or greater
*2: LabVIEW Driver is the trademark or registered trademark of National Instruments. 
Power supply 100 V to 240 V AC, 50 Hz/60 Hz, Rated power consumption: 40 VA max.
Normal power consum

Basic specifications

Accuracy guaranteed: 1 year

Resistance range (13 ranges) [Range, Maximum display value, Resolutions, Testing current (Measurement current) ]
1000 μΩ: 1200.000 μΩ, 1 nΩ, 1 A
10 mΩ: 12.000 00 mΩ, 10 nΩ, 1 A
100 mΩ: 120.000 0 mΩ, 100 nΩ, 1 A
1000 mΩ: 1200.000 mΩ, 1 μΩ, 100 mA
10 Ω: 12.000 00 Ω, 10 μΩ, 10 mA
100 Ω: 120.000 0 Ω, 100 μΩ, 10 mA
1000 Ω: 1200.000 Ω, 1 mΩ, 1 mA
10 kΩ: 12.000 00 kΩ, 10 mΩ, 1 mA
100 kΩ: 120.000 0 kΩ, 100 mΩ, 100 μA
1000 kΩ: 1200.000 kΩ, 1 Ω, 10 μA
10 MΩ 12.000 00 MΩ, 10 Ω, 1 μA
100 MΩ (100 MΩ range high-precision mode): 120.000 0 MΩ, 100 Ω, 100 nA
1000 MΩ: 1200.0 MΩ, 100 kΩ, 1 μA or less
Representative accuracy (High mode, OVC function enabled, SLOW2, no zero adjustment) 1000 μΩ range: ±0.045% rdg ±0.010 % f.s.
10 mΩ range: ±0.045% rdg ±0.001 % f.s.
100 mΩ range: ±0.045% rdg ±0.001 % f.s.
1000 mΩ range: ±0.012% rdg ±0.001 % f.s.
1000 Ω range: ±0.006% rdg ±0.001 % f.s.
Testing current (Measurement current) High mode: 1000μΩ (1 A) to 1000 MΩ (up to 1 μA)
Low mode: 100 mΩ (100 mA) to 100 Ω (1 mA)
Low power mode (LP): Low power measurement with measurement current and open circuit voltage down to 20 mV
LP1000 mΩ (1 mA) to LP1000 Ω (5 μA)
Measurement speed Representative value: FAST (2.3 ms) / MED (50 Hz: 22 ms, 60 Hz: 19 ms) / SLOW1 (102 ms) / SLOW2 (202 ms)
PR10 mΩ range*: FAST (21 ms) / MED (50 Hz: 41 ms, 60 Hz: 37 ms) / SLOW1 (121 ms) / SLOW2 (221 ms)
Path resistance tolerance (reference values)
Path resistance between SOURCE B and SOURCE A (other than measurement target)
Range: 100 mΩ or less (PR* mode off) : 2.6 Ω
Range: 100 mΩ or less (PR* mode on) : 3.5 Ω
Range: 1000 mΩ: 15 Ω
Range: 10 Ω : 150 Ω
Range: 100 Ω : 100 Ω
Range: 10 kΩ : 500 Ω
Range: 100 kΩ or greater: 1 kΩ
Maximum open-termin al voltage Range: 1000 Ω or less: 8.0 V
Range: 10 kΩ or greater: 20 V
Temperature measurement Temperature Sensor (Z2001[included accessories]): -10.0℃ to 99.9℃
Analog input (Ex: Infrared thermometer): DC 0 V to 2.0 V
Multiplexer (built-in option)*
*RM3545A-2 only
Multiplexer unit Z3003
Number of installable units:Max. 2
Maximum number of channels : 20 channels (4-wire method), 42 channels (2-wire method)
Switching time : 30 ms
Multiplexer (external option) Switch Mainframe
Maximum number of channels (SW1001): 33 channels (4-wire method)
Maximum number of channels (SW1002): 132 channels (4-wire method)
Switching time:11 ms
Communication interfaces LAN (TCP/IP, 10BASE-T/100BASE-TX), RS-232C (Max. 115200 bps, also used as printer interface), USB, EXT I/O (D-sub 37-pin, Analog output (D/A output voltage range: DC 0 V to 1.5 V )
Functions Contact check, Zero adjustment (within each range ±50% f.s.) *1, Zero-adjustment-free accuracy guaranteed, OVC function, Contact improvement function (max. applied voltage: 5V; max. applied current: 10 mA), Low-power mode (maximum open voltage: 20 mV), Auto-hold function, Comparator, Temperature measurement function, Temperature correction (TC) function, Temperature conversion (ΔT) function, Statistical calculation function, Delay function, Averaging function, Saving panels (saving of measurement conditions), Data memory function, Command monitor function (display of send/receive status of commands and queries),LabVIEW® Driver compatible*2
*1: Zero adjustment forcibly disabled for 100 MΩ or greater
*2: LabVIEW Driver is the trademark or registered trademark of National Instruments. 
Power supply 100 V to 240 V AC, 50 Hz/60 Hz, Rated power consumption: 40 VA max.
Normal power consumption (Reference value) 16 W (Testting current 1 A, LCD on)
Dimensions and mass RM3545A-1: 215 mm (8.46 in) W × 80 mm (3.15 in) H × 306.5 mm (12.07 in) D, 2.7 kg (95.2 oz)
RM3545A-2: 215 mm (8.46 in) W × 80 mm (3.15 in) H × 306.5 mm (12.07 in) D, 3.4 kg (119.9 oz)
Included accessories Power cord ×1, Temperature sensor Z2001 ×1, Male EXT I/O connector ×1, EXT. I/O connector cover ×1, Spare fuse (F1.6AH 250 V)×1, Start up guide ×1, Operating Precautions ×1, Instruction manual ×1
ption (Reference value)
16 W (Testting current 1 A, LCD on)
Dimensions and mass RM3545A-1: 215 mm (8.46 in) W × 80 mm (3.15 in) H × 306.5 mm (12.07 in) D, 2.7 kg (95.2 oz)
RM3545A-2: 215 mm (8.46 in) W × 80 mm (3.15 in) H × 306.5 mm (12.07 in) D, 3.4 kg (119.9 oz)
Included accessories Power cord ×1, Temperature sensor Z2001 ×1, Male EXT I/O connector ×1, EXT. I/O connector cover ×1, Spare fuse (F1.6AH 250 V)×1, Start up guide ×1, Operating Precautions ×1, Instruction manual ×1

Interested in this product?

Contact us via WhatsApp for more information, pricing, or to place an order.

Contact Us on WhatsApp
WhatsApp Chat