Fluke 289 True-RMS Data Logging Multimeter
The reliable Fluke 289 True-RMS Data Logging Multimeter
Product Overview
Fluke 289 True-RMS Data Logging Multimeter displays results in Trend Capture graphical form via a 50,000-swell going on dot matrix display and can communicate data wirelessly to smartphones and computers. You can get this Fluke 289 True RMS data logging multimeter at the best price in Bangladesh.
What makes Fluke 289 an each and all one-circular acceptable is that it is in addition to an excellent multimeter furthermore most test ranges apropos the ship. This is backed taking area by a high level of correctness and utter. This Fluke meter not on your own permissible for both electrical and electronic come to but along within the auditorium or on the bench.
Despite sentient thing more fit for the bench upon account of its hefty size, the 289 is a multimeter first and a data logger second. It easily conflict in tab to every one of of fields, including AC/DC voltage and millivolts, all current ranges (amps, milliamps, and micro-amps), continuity and resistance, frequency, capacitance, loyalty cycle and pulse width, conductance, DVB, and temperature.
The main and best feature of the Fluke 289 is its exceptional data logger. It can buildup going upon to 15,000 recorded deeds and has TrendCapture facility for that reason you can psychoanalysis graphs in-situ. There's in addition to a definite-become tallying clock for period-stamping and data can be sent off to a smartphone or PC via Bluetooth.
Key features: Fluke 289 True-RMS Data Logging Multimeter
- Zoom on trend provides unprecedented ability to view and analyze TrendCapture data; zoom in up to 14 times.
- Share results with your team using ShareLive™ video call (requires ir3000 FC wireless connector [sold separately] and no-cost Fluke Connect mobile app).
- TrendCapture graphically displays logged data session to quickly determine whether anomalies may have occurred.
- Selectable AC filter (smoothing mode) helps display a steadier reading when the input signal is changing rapidly or noisy.
- Low Pass filter for accurate voltage and frequency measurements at the same time on adjustable speed motor drives and other electrically noisy equipment.
- LoZ Volts. Low impedance voltage function for eliminating ghost voltages. Also recommended when testing for absence or presence of live power.
- Adjustable recording and auto hold thresholds, specify a percentage change in the readings that begins a new event.
- Large 50,000 count, 1/4 VGA dot matrix display with white backlight.
- Logging function with expanded memory for unattended monitoring of signals over time. Using on-board TrendCapture users can graphically review logged readings without needing a PC. Store up to 15,000 recorded events.
- Save multiple logging sessions before PC download is necessary.
- Two terminal 50 ohm range with 1 milliohm resolution, 10 mA source current. Useful for measuring and comparing differences in motor winding resistance or contact resistance.
- On board help screens for measurement functions. Unsure about a function - go to that function and press the "i" button.
- Real time clock for automatic time stamping of saved readings.
- Relative mode to remove test lead resistance from low ohms or capacitance measurements.
- True-RMS AC voltage and current for accurate measurements on non-linear signals.
- Measure up to 10 A (20 A for 30 seconds).
- 100 mF capacitance range.
- FlukeView forms enable you to document, store and analyze individual readings or a series of measurements, then convert them into professional-looking documents.
- Optional magnetic hanger for easy setup and viewing while freeing your hands for other tasks.
- Peak capture to record transients as fast as 250 μs.
- Premium test leads and alligator clips included.
- Amp jack plugs included.
- Limited lifetime warranty.
Specifications
Specifications: Fluke 289 True-RMS Data Logging Multimeter
| Specifications | ||
| Function | ||
| DC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
| Basic accuracy | 0.025% | |
| AC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
| Basic accuracy | 0.4% (True-RMS) | |
| DC current | Range / resolution | 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
| Basic accuracy | 0.05% | |
| AC current | Range / resolution | 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
| Basic accuracy | 0.6% (True-RMS) | |
| Temperature (excluding probe) | Range / resolution | -200.0°C to 1350.0°C (-328.0°F to 2462.0°F) |
| Basic accuracy | 1.0% | |
| Resistance | Range / resolution | 50.000 Ω, 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ |
| Basic accuracy | 0.05% | |
| Capacitance | Range / resolution | 1.000 nF,10.00 nF 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF |
| Basic accuracy | 1.0% | |
| Frequency | Range / resolution | 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
| Basic accuracy | 0.005% | |
| Connectivity | Optional infrared connector via Fluke ir3000 FC | |
| General Specifications | ||
| Maximum voltage between any terminal and earth ground | 1000 V | |
| Battery type | 6 AA alkaline batteries, NEDA 15A IECLR6 | |
| Battery life | 100 hours minimum, 200 hours in logging mode | |
| Temperature | Operating | -20°C to 55°C |
| Storage | -40°C to 60°C | |
| Relative humidity | 0 to 90% (0 to 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to 55°C) | |
| Electromagnetic compatibility | EMC EN61326–1 | |
| Vibration | Random vibration per MIL-PRF-28800F Class 2 | |
| Shock | 1 meter drop per IEC/EN 61010–1 3rd Edition | |
| Size (H x W x L) | 22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in) | |
| Weight | 870.9 g (28 oz) | |
| Multiple on screen displays | Yes | |
| True-RMS AC bandwidth | 100 kHz | |
| dBV/dBm | Yes | |
| DC mV resolution | 1 μV | |
| Megohm range | Up to 500 MΩ | |
| Conductance | 50.00 nS | |
| Continuity beeper | Yes | |
| Battery/fuse access | Yes/Yes | |
| Elapse time clock | Yes | |
| Time of day clock | Yes | |
| Min-max-avg | Yes | |
| Duty cycle | Yes | |
| Pulse width | Yes | |
| Isolated optical interface | Yes | |
| Auto/touch hold | Yes | |
| Reading memory | Yes | |
| Log to PC | Yes | |
| Interval/event logging | Yes | |
| Logging memory | Up to 15,000 readings | |
| Wireless connectivity (optional) | Yes | |