Fluke 568 Contact & Infrared Temperature Gun
Dual measurement power for precise industrial temperature control
Product Overview
Fluke 568 Contact & Infrared Temperature Gun Price in Bangladeh
Fluke 568 Contact & Infrared Temperature Gun Price in Bangladesh is a highly searched topic among professionals who require a versatile and high performance temperature measurement solution. This advanced device combines both infrared and contact measurement capabilities, making it a powerful tool for industrial diagnostics and maintenance tasks.
The thermometer offers a wide infrared temperature measurement range from minus forty degrees Celsius to eight hundred degrees Celsius, allowing users to measure extreme temperatures safely without direct contact. In addition, it supports K type thermocouple input, enabling contact measurement for more precise readings when required.
One of the standout features of this device is its dual functionality. Users can switch between non contact infrared measurement and contact measurement depending on the application. This flexibility makes it suitable for a wide range of industries including electrical maintenance HVAC systems mechanical inspections and manufacturing processes.
The device is equipped with a 50 to 1 distance to spot ratio, allowing accurate measurement of small objects from a safe distance. This is particularly useful when working with high temperature or hazardous equipment. The built in laser targeting system helps improve precision by clearly identifying the measurement area.
Another important feature is its data logging capability. The thermometer can store up to ninety nine measurement points, which can be transferred to a computer via USB for analysis and reporting. It also includes FlukeView software that helps users track temperature trends and generate professional reports.
The device supports adjustable emissivity along with a built in material table, ensuring accurate readings across different surfaces such as metals plastics and ceramics. It also includes advanced functions like minimum maximum average and differential readings, along with high and low alarms for quick detection of abnormal conditions.
Designed for durability, the thermometer features a rugged ergonomic construction that can withstand demanding industrial environments. Its intuitive menu driven interface and backlit display make it easy to use even in low light conditions. The long battery life and USB power option further enhance its usability for extended operations.
Overall, this contact and infrared temperature gun is an excellent choice for professionals who need flexibility, accuracy, and reliability in one device. It helps improve efficiency, reduce risk, and ensure precise temperature monitoring across various industrial applications in Bangladesh.
Key Features: Fluke 568 Contact & Infrared Temperature Gun
- Combines the functionality of both contact and non-contact thermometers in a single device
- Capable of accurately measuring a wide temperature range, from -40°C to 800°C (-40°F to 1472°F), with precision up to +1.0°C or +1.0% of the reading (whichever is greater)
- Boasts a robust, ergonomic design built to withstand challenging industrial, electrical, and mechanical settings
- Provides an impressive distance-to-spot ratio of 50:1, ensuring accurate measurements from a safe distance
- Compatible with the majority of K-type thermocouples, offering versatility and convenience
Specifications
Specifications: 568 Contact & Infrared Temperature Gun
| Product Specifications | ||
| Infrared temperature range | -40°C to 800°C (-40°F to 1472°F) | |
| Infrared accuracy | < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F); | |
| > 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater | ||
| Display resolution | 0.1°C / 0.1°F | |
| Infrared spectral response | 8 µm to 14 µm | |
| Infrared response time | < 500 msec | |
| Thermocouple Type-K input temperature range | -270°C to 1372°C (-454°F to 2501°F) | |
| Thermocouple Type-K input accuracy | -270°C to -40°C | ±(1°C + 0.2°/1°C) (-454°F to -40°F: ±(2°F + 0.2°/1°F)) |
| -40°C to 1372°C | ±1% or 1°C (-40°F to 2501°F: ±1% or 2°F), whichever is greater | |
| D:S (distance to measurement spot size) | 50:1 | |
| Laser sighting | Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm | |
| Minimum spot size | 19 mm (0.75 in) | |
| Emissivity adjustment | By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 | |
| Data storage with date/time stamp | 99 points | |
| PC interface and cable | USB 2.0 with FlukeView® Forms software | |
| Hi/Low alarms | Audible and two-color visual | |
| Min/Max/Avg/Dif | Yes | |
| Display | Dot matrix 98 x 96 pixels with function menus | |
| Backlight | Two levels, normal and extra bright for darker environments | |
| Trigger lock | Yes | |
| Switchable Celsius and Fahrenheit | Yes | |
| Power | 2 AA/LR6 Batteries and USB when used with a PC | |
| Battery life | If used continuously | Laser and backlight on,12 hours; laser and backlight off, 100 hours |
| Operating temperature | 0°C to 50°C (32°F to 122°F) | |
| Storage temperature | -20°C to 60°C (-40°F to 140°F) | |
| Bead thermocouple Type-K range | -40°C to 260°C (-40°F to 500°F) | |
| Bead thermocouple Type-K accuracy | ±1.1°C (2.0°F) from 0°C to 260°C (32°F to 500°F), typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F) | |