Fluke 568 Ex Intrinsically Safe Infrared Thermometer

  • Home
  • Products
  • Fluke 568 Ex Intrinsically Safe Infrared Thermometer
Fluke 568 Ex Intrinsically Safe Infrared Thermometer

Fluke 568 Ex Intrinsically Safe Infrared Thermometer

Safe and precise temperature measurement for hazardous industrial environments

Product Overview

Fluke 568 Ex Intrinsically Safe Infrared Thermometer Price in Bangladesh

Fluke 568 Ex Intrinsically Safe Infrared Thermometer Price in Bangladesh is a highly searched topic among professionals working in hazardous industrial environments where safety and accuracy are critical. This advanced thermometer is specially designed for use in explosive or high risk areas such as oil and gas plants chemical industries and heavy manufacturing sectors.

The device combines both infrared and contact temperature measurement capabilities, allowing users to measure surface temperatures without contact or use a K type thermocouple for direct measurement when higher accuracy is needed. It supports a wide temperature range from minus forty degrees Celsius to eight hundred degrees Celsius, making it suitable for a variety of demanding industrial applications.

One of the key features of this thermometer is its intrinsically safe certification, which ensures safe operation in potentially explosive atmospheres. This makes it a trusted tool for professionals working in environments where standard electronic devices may pose risks. It is designed to meet strict safety standards while maintaining high performance and reliability.

The device also features a 50 to 1 distance to spot ratio, allowing users to measure small or distant targets safely and accurately. A single laser targeting system helps improve precision by clearly indicating the measurement point, reducing the chances of errors during inspection tasks.

It includes advanced functions such as MIN MAX AVG and differential readings, along with adjustable emissivity settings to ensure accurate measurements across different materials. The built in data logging capability allows users to store multiple readings for later analysis, improving documentation and reporting efficiency in industrial workflows.

The Fluke 568 Ex is designed with durability and ease of use in mind. Its rugged construction ensures reliable performance in harsh working conditions, while the intuitive interface allows quick switching between infrared and contact modes. The ergonomic design makes it comfortable to use during long field operations.

Overall, this intrinsically safe infrared thermometer is an excellent choice for professionals who require maximum safety, high accuracy, and dual measurement capability. It plays a vital role in improving operational safety, enhancing maintenance efficiency, and supporting critical decision making in hazardous industrial environments across Bangladesh.

Key Features: Fluke 568 Ex Intrinsically Safe Infrared Thermometer

  • Intrinsically safe infrared and contact thermometer
  • Meets intrinsically safe certifications in Class I Div. 1 and Div. 2 or Zone 1 and 2 hazardous environments
  • Measures temperatures from -40°C to 800°C (-40°F to 1472°F)
  • Comes with a conductive case to safely carry the IR thermometer into hazardous areas
  • Offers a distance-to-spot ratio of 50:1
Specifications

Specifications: Fluke 568 Ex Intrinsically Safe Infrared Thermometer

Specifications
Infrared temperature range -40°C to 800°C (-40°F to 1472°F)
Infrared accuracy < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F);
> 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater
Display resolution 0.1°C / 0.1°F
Infrared spectral response 8 µm to 14 µm
Infrared response time < 500 ms
Thermocouple type-k input temperature range -270°C to 1372°C (-454°F to 2501°F)
Thermocouple type-k input accuracy < -40°C: ±(1°C + 0.2°/1°C)
≥ -40°C: ±1% or 1°C, whichever is greater < -40°F: ±(2°F + 0.2°/1°F)
≥ -40°F: ±1% or 2°F, whichever is greater
D:S (distance to measurement spot size) 50:1
Laser sighting Single-point laser
Minimum spot size 19 mm (0.75 in)
Emissivity adjustment By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage 99 points
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Display Dot matrix with function menus
Backlight Two levels, normal and extra bright for darker environments
Trigger lock Yes
Switchable celsius and fahrenheit Yes
Power 2 AAA/LR03 type-approved batteries (For a list of type-approved batteries, refer to Product Safety Instructions.)
Battery life 4 hours with laser and backlight on;
100 hours with laser and backlight off, at 100% duty cycle
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-40°F to 140°F)
Bead thermocouple type-k range -40°C to 260°C (-40°F to 500°F)
Bead thermocouple type-k accuracy ±1.1°C (2.0°F) from 0°C to 260°C (32 °F to 500°F),
typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)