Fluke ii500 Acoustic Imager
Visualize sound for faster leak detection and industrial maintenance
Product Overview
Fluke ii500 Acoustic Imager Price in Bangladesh
Fluke ii500 Acoustic Imager Price in Bangladesh is a widely searched topic among industrial professionals who need an advanced and reliable solution for detecting compressed air leaks gas leaks and vacuum system issues. This acoustic imaging camera is designed to visualize sound, helping maintenance teams quickly identify problems that are difficult to detect using traditional methods.
The device uses advanced SoundMap technology to convert sound waves into a visual image overlaid on a real time display. This allows users to clearly see the exact location of leaks or abnormal sound sources even in noisy industrial environments. It operates within a frequency range of approximately 2 to 52 kHz, making it highly effective for identifying hidden issues in machinery and piping systems.
One of the key advantages of this acoustic imager is its ability to simplify leak detection processes. It supports LeakQ mode which helps estimate leak severity and prioritize maintenance actions. This makes it especially useful for energy audits and preventive maintenance programs where efficiency and cost reduction are important.
The Fluke ii500 features a large touchscreen display and an ergonomic handheld design, making it easy for technicians to operate even with minimal training. It is built for industrial environments and offers a rugged structure that ensures durability during field use. Its design allows users to perform inspections safely from a distance without interrupting ongoing operations.
Another important feature is its ability to work effectively in high noise environments. By isolating specific sound frequencies, it filters background noise and highlights only relevant acoustic signals. This improves accuracy and reduces the time required to locate faults in complex systems.
The device is widely used in industries such as manufacturing HVAC systems power plants and oil and gas facilities. It helps organizations reduce energy loss improve equipment reliability and enhance overall operational safety. With its advanced acoustic imaging technology it plays a crucial role in predictive maintenance strategies.
In summary the Fluke ii500 Acoustic Imager is a powerful diagnostic tool that transforms how professionals detect and analyze industrial leaks. Its combination of ease of use advanced sound visualization and rugged design makes it a valuable solution for industries in Bangladesh looking to improve efficiency and maintenance accuracy.
Key Features: Fluke ii500 Acoustic Imager
- Easy, fast, and safe visual detection of compressed gas leaks.
- The 7" LCD touchscreen displays a SoundMap™ over visual images, making it easier to locate leaks quickly.
- Intuitive interface requires no training for maintenance teams.
Specifications
Specifications: Fluke ii500 Acoustic Imager
| Specifications | |
| Key Features | ii500 |
| Sensors | |
| Frequency band | 2 kHz to 52 kHz |
| Detection range1 | 0.5 to > 50 meters (1.6 to > 164 feet) |
| Field of view (FOV) | 63°± 5° |
| Nominal frame rate | 25 FPS |
| Built-in digital camera (visible light) | |
| Field of view (FOV) | 63°± 5° |
| Focus | Fixed lens |
| Zoom | No zoom |
| Resolution | 0.3 MP |
| Display | |
| Size | 7" LCD with backlight, sunlight readable |
| Resolution | 1280 x 800 (1,024,000 pixels) |
| Touchscreen | Capacitive |
| Acoustic image | SoundMapTM image | < /tr>
| Image storage | |
| Storage capacity | 20 GB (> 5,000 pictures / > 999 videos) |
| Image format | Blended visual and SoundMapTM .JPG or .PNG |
| Video format | Blended visual and SoundMapTM .MP4 |
| Video length | Up to 5 minutes |
| Digital export | USB-C for data transfer |
| Acoustic measurements | |
| Measurement range (typical) | 15.4 to 115.2 dB SPL (± 1 dB SPL 2 kHz) 5.6 to 102.5 dB SPL (± 2 dB SPL 19 kHz) 28.4 to 131.1 dB SPL (± 1 dB SPL 35 kHz) 41.8 to 133.1 dB SPL (± 3 dB SPL 52 kHz) |
| Classification and quantification | |
| LeakQTM | Leak size scale (1-10) |
| PDQ ModeTM | – |
| MecQTM | – |
| Auto max/min dB gain | Auto |
| Frequency band selection | User selectable through user-made presets or manual entry |
| Battery | |
| Battery | Rechargeable and field replaceable Li-ion battery |
| Battery life | 6 hours |
| Battery charging time | 3 hours |
| Battery charging system | External (Bay charger) |
| Software | |
| Ease of use | Intuitive user interface |
| Acoustics: Show dB scale | On/Off |
| Acoustics: Min/Max dB | Manual/Auto |
| Acoustics: Profiles | – |
| Acoustics: High frequency | – |
| Acoustics: Multiple sources | Single source |
| Palette: Colors | 3: Grayscale, Ironbow, and Blue-Red |
| Palette: Overly transparency | Yes: 1-100 % |
| Grayscale mode | Yes |
| Centerpoint markers | On/Off |
| Trend graphs | Frequency and dB scale |
| Spotmarkers | dB level reading at center point of image |
| Leak values | LeakQTM scale (1-10) |
| Master admin menu | – |
| Annotation | Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure |
| Photo notes | Up to 4 photos notes for reference |
| Asset inspection status | – |
| Asset ID | Text input and automatic QR code based asset ID identification |
| Actions annotation | – |
| Other | – |
| General specifications | |
| Tripod holder / connector | – |
| USB | 1 x USB-C |
| Wireless | – |
| Operating Temperature | -10 to 45 °C (14 to 113 °F) |
| Storage Temperature | -20 to 70 °C (-4 to 158 °F) without batteries installed |
| Relative humidity | 10 to 95 % non-condensing |
| Size (H x W x L) | 186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches) |
| Weight (battery included) | 2.1 kg (4.6 pounds) |
| Ingress Protection (IP) | IP40 |
| Warranty | 2 year |
| Fluke Premium Care | Premium Care Standard2 |
| Self-diagnostic notification | Array-health test to identify when microphone array needs attention |
| Supported languages | Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Simplified Chinese, Spanish, Swedish, Traditional Chinese |
| RoHS compliant | Yes |
| Safety | |
| General safety | IEC 61010-1: Pollution degree 2 |
| Electromagnetic Compatibility (EMC) International | IEC 61326-1: Portable Electromagnetic Environment, CISPR 11: Group 1, Class A |
| Korea (KCC) | Class A Equipment (Industrial Broadcasting and Communication) |
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 |