Fluke TiS55+ Thermal Camera
Precision thermal imaging built for real world industrial performance
Product Overview
Fluke TiS55+ Thermal Camera Price in Bangladesh
Fluke TiS55+ Thermal Camera Price in Bangladesh is a popular search among professionals who are looking for a dependable and efficient thermal imaging device for industrial and maintenance purposes. This thermal camera is designed to deliver accurate temperature measurements and high quality thermal images that help users detect issues quickly and efficiently.
The device is widely used in electrical inspections mechanical troubleshooting building diagnostics and preventive maintenance. With its rugged design it can withstand harsh working environments making it suitable for field technicians engineers and industrial professionals. The camera offers clear infrared imaging which helps identify heat patterns leaks insulation problems and electrical faults without direct contact.
One of the key highlights of this thermal camera is its ease of use. It features an intuitive interface that allows users to capture and analyze images without requiring extensive training. The built in features enhance productivity by allowing quick documentation and reporting. Users can store images and transfer data easily for further analysis and reporting purposes.
Another important aspect is its durability and portability. The compact design makes it easy to carry and use in different locations while maintaining strong performance. It also includes advanced imaging technology that improves visibility and ensures precise diagnostics even in challenging conditions.
This thermal camera is an excellent choice for professionals who prioritize reliability efficiency and accuracy in their work. Whether it is used for routine inspections or complex troubleshooting tasks it provides consistent performance and valuable insights. The demand for this device in Bangladesh continues to grow as industries increasingly adopt advanced tools for maintenance and safety.
Overall this thermal imaging solution stands out as a powerful tool that enhances operational efficiency reduces downtime and supports better decision making across various industries.
Key Features: Fluke TiS55+ Thermal Camera
- 256 x 192 infrared resolution
- Asset Tagging
- Touchscreen IR Fusion™
- Manual and fixed focus
- Measure up to 550 °C
- Engineered to withstand 2 meter drop
Specifications
Specifications: Fluke TiS55+ Thermal Camera
| Key Features | TiS55+ |
| Infrared resolution | 256 x 192 (49,152 pixels) |
| IFOV | 1.91 mRad |
| Field of view | 28° x 20° |
| Minimum focus distance | 0.15 m |
| Focus system | Manual focus |
| Wireless connectivity | Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi and LAN (where available) |
| Fluke Connect app compatible | Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing |
| Fluke Connect Assets optional software | Yes*, assign images to assets and create work orders. Easily compare measurement types - whether mechanical, electrical or infrared images - in one location |
| Asset Tagging | Scan a QR code to automatically organize and file thermal images with Fluke Connect™ |
| IR-Fusion technology | AutoBlend continuous 0 % to 100 %. Adds the context of the visible details to your infrared image |
| Picture-InPicture (PIP) | Yes |
| Display | 3.5" (8.9 cm landscape) touchscreen 640 x 480 LCD |
| Ergonomic design | Designed for one-handed use |
| Thermal sensitivity | 40mk |
| Level and span | Smooth auto and manual scaling |
| Fast auto-rescale in manual mode | Yes |
| Minimum span (in manual mode) | 3°C (4.5 °F) |
| Minimum span (In auto mode) | 5°C (9.0 °F) |
| Built-in digital camera (visible light) | 5mp |
| Frame rate | 9 Hz or 27 Hz models |
| Dew point calculation | No |
| Data storage and image capture | |
| Internal memory | ∼500 images |
| External memory | ≥4 GB SD card (>1000 images) |
| Image capture, review, save mechanism | One-handed image capture, review, and save capability |
| Image file formats | Non-radiometric BMP or JPEG or fully-radiometric is2 |
| Memory review | Yes |
| Software | Fluke Connect software—full analysis and reporting software with access to the Fluke Connect |
| Analyze and store radiometric data on a PC | Yes |
| Export file formats with Fluke Connect software | is2, BMP, GIF, JPEG, PNG, TIFF |
| Voice annotation | Yes, 60 second maximum audio recording via Bluetooth Audio Headset Profile (HSP) connection to external device. |
| IR-PhotoNotes | Yes. Up to 1 extra user-selectable visible light image capture to be included in IS2 file. |
| Text annotations | After IS2 capture, user can type in a note using on-screen keyboard. |
| Video recording and formats | No |
| Remote control operations | No |
| Auto capture (temperature and interval) | Yes. User-selectable time interval for capturing IS2 or Jpeg files. |
| Battery | |
| Batteries (field-replaceable, rechargeable) | Lithium-ion rechargeable battery |
| Battery life | ≥3.5 hours continuous without WiFi (Actual life depends on settings and usage) |
| Battery charging time | ≤2.5 hours to full charge |
| Battery charging system | Ti SBC3B Two-Bay Battery Charger or in-Imager charging. (does not come with two-bay battery charger) |
| AC operation | AC operation with included power supply, universal adapters included Output: 15 VDC, 2 A |
| Power saving | User-selectable sleep and power off |
| Temperature measurement | |
| Temperature range (not calibrated below -10 °C) | -20 °C to 550 °C (not calibrated below -10 °C) |
| Accuracy | ±2 °C or 2 % (whichever is greater) at 25 °C ambient temperature |
| On-screen emissivity correction | Yes, “top ten” material list plus numerical adjustment between 0.01 and 1.00 |
| Color palettes | |
| Standard palettes | 6 |
| General specificiations | |
| Color alarms | Yes |
| Infrared spectral band | ~8-14μm |
| Operating temperature | -10 °C to 50 °C (14 °F to 122 °F) |
| Storage temperature | -20 °C to 50 °C (-4 °F to 122 °F) without batteries |
| Relative humidity | 10 % to 95 % non-condensing |
| Spot temperature | Center spot (unmovable) |
| User-definable spot markers | Yes, 3 user-adjustable spot markers for a single pixel each. Position is adjustable. Temperature value for marker shown on screen. User can choose to switch display on/off for each marker. |
| User defined measurement boxes | Yes, 3 user-adjustable rectangles. Size and position are adjustable. Rectangle statistics shown on screen: Min, Max, Average temperature. User can choose to switch display on/off for each marker. |
| Hard case | Rugged hard carrying case with soft transport bag, including adjustable strap |
| Safety standards | IEC 61010-1: Pollution Degree 2 |
| Electromagnetic combability | IEC 61326-1: Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A |
| Australian RCM | RCM IEC 61326-1 |
| US FCC | 47 CFR 15 Subpart C Sections 15.207, 15.209, 15.249 |
| Vibration | 10 Hz to 150 Hz, 0.15 mm, IEC 60068-2-6 |
| Shock | 30 g, 11 ms, IEC 60068-2-27 |
| Drop | Engineered to withstand 2M drop |
| Sized (H x W x L) | ∼(26.7 cm x 10.1 cm x 14.5 cm) ∼ (10.5 in x 4.0 in x 5.7 in) |
| Weight (battery included) | 0.885 kg (1.95 lbs) |
| Enclosure rating | IP54 |
| Warranty | Two-years (standard) |
| Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
| Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
| RoHS compliant | Yes |