Hioki dt4253 digital multimeter
Advanced True RMS multimeter designed for HVAC diagnostics and precise electrical measurement
Product Overview
Hioki DT4253 Digital Multimeter
Hioki DT4253 Digital Multimeter Price in Bangladesh is a professional grade measurement tool designed for electricians, HVAC technicians, and maintenance engineers who require precise and reliable electrical diagnostics. This multimeter belongs to the Hioki DT4200 series, which is known for high accuracy, advanced safety standards, and durable construction suitable for demanding electrical environments.
The Hioki DT4253 supports a wide range of measurement functions including AC and DC voltage testing, resistance measurement, continuity testing, capacitance, and frequency measurement. It also includes True RMS capability, which allows the multimeter to measure distorted or non-sinusoidal signals accurately. This feature is especially important when working with modern electrical systems such as inverters, variable frequency drives, and electronic equipment.
One of the standout features of the Hioki DT4253 is its ability to measure very small currents ranging from microamps to milliamps, which is particularly useful when testing instrumentation signals or flame currents in gas-burning equipment. The device can also convert and display 4 to 20 mA instrumentation signals into percentage values, making it ideal for industrial monitoring systems and sensor diagnostics.
The multimeter also supports temperature measurement using a thermocouple probe, allowing technicians to monitor heating systems, air conditioning equipment, and other temperature-dependent devices. With measurement capability from −40°C to 400°C, the DT4253 becomes an excellent tool for HVAC maintenance and troubleshooting.
Ease of use is another advantage of this multimeter. The Hioki DT4253 features a clear dual digital display with a bar graph that allows technicians to view voltage and frequency simultaneously. Auto ranging functionality simplifies the measurement process by automatically selecting the appropriate range, reducing errors and saving time during diagnostics.
In terms of safety and reliability, the device is rated CAT IV 600V and CAT III 1000V, ensuring safe operation in high-energy electrical environments such as distribution panels and industrial systems. The rugged construction and ergonomic design make it comfortable to use during long field operations while maintaining long-term durability.
Hioki DT4253 Digital Multimeter Price in Bangladesh reflects the value of a professional measurement instrument that combines True RMS accuracy, temperature testing capability, and advanced diagnostic functions. It is a dependable choice for technicians who require high precision, reliable safety features, and versatile measurement performance in daily electrical and HVAC maintenance work.
Key Features: Hioki DT4253 Digital Multimeter
- Ideal for measuring currents ranging from instrumentation signals (4 to 20 mA) to flame currents (μA) with built in high-sensitivity current ranges (DT4253)
- Dual display lets you check voltage and frequency simultaneously
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
Specifications
Specifications: Hioki DT4253 Digital Multimeter
| DC Voltage range | 600.0 mV to 1000 V 5 ranges, Basic accuracy: ±0.3 % rdg. ±5 dgt. |
|---|---|
| AC Voltage range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
| AUTO AC/DCV | Yes |
| Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±5 dgt. |
| DC Current range | 60.00 μA to 60.00 mA, 4 ranges, Basic accuracy: ±0.8 % rdg. ±5 dgt. |
| From 4 to 20mA Percentage conversion display | Yes |
| AC Current range (use with Clamp on probes) | 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
| Temperature (thermocouples) | K: -40.0 to 400.0 °C , Add the Temperature probe accuracy to basic accuracy: ±0.5 % rdg. ±2 °C |
| Voltage detection | N/A |
| Capacitance range | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt. |
| Frequency range | 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage), Basic accuracy: ±0.1 % rdg. ±1 dgt. |
| Continuity check | Continuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more |
| Diode test | Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V |
| Other functions | Filter function, Display value hold, Auto hold, Max/Min/Average value display, Relative display, Auto-power save, USB communication (option) |
| Display | Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph |
| Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s) |
| Power supply | LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF) |
| Dimensions and mass | 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D, 390 g (13.8 oz) (including batteries and holster) |