Hioki DT4282 digital multimeter
Premium high-precision digital multimeter designed for advanced industrial and laboratory electrical testing.
Product Overview
Hioki DT4282 Digital Multimeter Price in Bangladesh
Hioki DT4282 Digital Multimeter Price in Bangladesh is a high-end professional electrical testing instrument developed for engineers, technicians, researchers, and industrial maintenance professionals who require extremely accurate and reliable measurement results. As part of the advanced DT4200 series, this digital multimeter offers exceptional precision, fast measurement response, and robust safety features, making it ideal for industrial diagnostics, research laboratories, and complex electrical troubleshooting.
The Hioki DT4282 supports a wide range of measurement functions including AC and DC voltage measurement up to 1000V, direct current measurement up to 10A, resistance measurement, capacitance testing, frequency measurement, diode testing, and continuity testing with an audible buzzer. The device also supports temperature measurement when used with a compatible thermocouple probe, allowing professionals to analyze electrical and thermal conditions in electronic systems and industrial equipment.
One of the key highlights of the Hioki DT4282 is its True RMS measurement capability, which ensures accurate readings even when measuring distorted or non-sinusoidal waveforms commonly found in modern electrical systems such as inverters, motor drives, and switching power supplies. The multimeter features a large 60,000-count dual LCD display, enabling users to view two measurement values simultaneously, such as voltage and frequency, which improves efficiency during diagnostics.
The device offers extremely high precision with ±0.025% basic DC voltage accuracy, making it suitable for high-precision electrical measurement tasks in laboratories and industrial environments. It also includes several advanced analysis functions such as MAX/MIN recording, peak value capture, relative measurement, data hold, and filtering functions that help technicians obtain stable readings when measuring noisy electrical signals.
Safety and reliability are important aspects of the Hioki DT4282 design. The multimeter complies with CAT IV 600V and CAT III 1000V safety standards, providing strong protection when working with high-voltage electrical systems. It also includes a terminal shutter safety mechanism that helps prevent incorrect probe insertion and reduces the risk of measurement errors or electrical accidents.
Another unique feature of the DT4282 is its ability to measure large currents using external clamp sensors, which eliminates the need to switch leads between current terminals and helps prevent short-circuit risks during measurement. This design improves safety and convenience for professionals performing electrical inspections.
Hioki DT4282 Digital Multimeter Price in Bangladesh reflects the value of a premium and highly accurate electrical testing tool designed for demanding professional applications. With advanced measurement functions, high-precision performance, and strong safety features, this multimeter is an excellent choice for engineers and technicians who require reliable and detailed electrical diagnostics in industrial and laboratory environments.
Key Features: Hioki DT4282 Digital Multimeter
- 60000 count, 5-digit display, high-resolution measurements
- ±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency characteristics
- The low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- Terminal shutter mechanism (prevents erroneous test lead insertion)
- Measure up to 10 A with direct input (DT4282 only)
- The dual display lets you check voltage and frequency simultaneously
Specifications
Specifications: Hioki DT4282 Digital Multimeter
Accuracy guaranteed: 1 year
Regarding DMM Accuracy: Due to a DMM's many ranges and functions, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.
| DC Voltage range | 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. | |||||
|---|---|---|---|---|---|---|
| AC Voltage* range | 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy 45 - 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3) |
|||||
| DC + AC Voltage* range | 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy 45 - 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3) |
|||||
| Resistance range | 60.000 Ω to 600.0 MΩ, 8 ranges, (Conductance: 600.00 nS, DT4282 only) Basic accuracy: ±0.03 % rdg. ±2 dgt. |
|||||
| DC Current range | 600.00 μA to 10.000 A, 6 ranges, Basic accuracy: ±0.05 % rdg. ±5 dgt. | |||||
| AC Current* range | 600.00 μA to 10.000 A, 6 ranges, Basic accuracy 45 - 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3) Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range) |
|||||
| AC Current* range (use with Clamp on probes) |
N/A | |||||
| Peak | DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated) AC V, DC/AC A measurement: Signal width 1 msec or more (single), 250 μsec or more (repeated) |
|||||
| Capacitance range | 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt. | |||||
| Continuity Check | Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more | |||||
| Diode test | Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages | |||||
| Frequency range | AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio) 99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt. |
|||||
| dB conversion | Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages Display the dB conversion value of AC voltage (DVB) |
|||||
| Temperature (thermocouples) |
K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F) Add the accuracy of the Thermocouple probe to the main unit accuracy: ±0.5 % rdg. ±3 °C |
|||||
| Other functions | Filter function (remove harmonic noise, use only at 600 V AC, and 1000 V AC ranges), display value hold, auto hold, MAX/MIN value display, PEAK value display, relative value display, sampling setting, internal memory (400 data), auto-power save, USB communication (option), miss-insertion prevention shutters, decibel conversion, 4-20 mA percentage conversion | |||||
| Display | Main and Sub displays: 5-digit LCD, max. 60000 digits | |||||
| Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s ) | |||||
| Power supply | LR6 (AA) alkaline batteries ×4, Continuous use: 100 hours | |||||
| Dimensions and mass | 93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries) | |||||
| Included accessories | Test Lead L9207-10 ×1, Instruction Manual ×1, LR6 Alkaline Battery ×4 | |||||