Fluke 355 True RMS 2000 A Clamp Meter
Heavy Duty Industrial Clamp Meter for High Current Precision Measurement
Product Overview
Fluke 355 True RMS 2000 A Clamp Meter Price in Bangladesh
Fluke 355 True RMS 2000 A Clamp Meter is a professional grade electrical testing solution providing tools that you can explore this Clamp Meter Price in Bangladesh and experience powerful high current measurement with extreme accuracy and durability. This model is designed for industrial engineers technicians and utility professionals who need reliable performance in demanding electrical environments.
Fluke 355 True RMS 2000 A Clamp Meter Price in Bangladesh is engineered to handle very high current measurement up to 2000A AC and DC with True RMS technology ensuring accurate readings even in non linear electrical systems. This makes it ideal for heavy industrial applications where electrical loads are complex and signal distortion is common. The device delivers stable and trustworthy results for critical diagnostics and maintenance work.
This Clamp Meter Price in Bangladesh supports essential measurement functions including voltage resistance frequency and inrush current measurement which is especially useful for motor and equipment startup analysis. It features a large jaw opening that allows users to clamp around thick conductors and multiple cables commonly found in industrial power systems.
Fluke 355 True RMS 2000 A Clamp Meter is built for professional reliability with a rugged design that ensures long term performance in harsh working environments. It also includes advanced safety ratings such as CAT IV 600V and CAT III 1000V which provide high level protection during electrical testing in industrial and utility applications.
The display system is designed for clear visibility and easy reading of measurements even in low light conditions which helps technicians work efficiently in field environments. Additional features like MIN MAX AVG recording and inrush current capture make it a complete diagnostic tool for advanced electrical analysis and troubleshooting.
Durability and precision make this clamp meter a trusted choice for professionals working in power plants factories and large scale electrical maintenance operations. Its strong build quality ensures consistent performance even under continuous heavy duty usage.
Overall the Fluke 355 True RMS 2000 A Clamp Meter Price in Bangladesh represents a premium level solution for high current electrical measurement. It delivers unmatched accuracy safety and reliability making it one of the most powerful clamp meters available for industrial use in Bangladesh.
Key features: Fluke 355 True RMS 2000 A Clamp Meter
- Reliably handle a wide range of high-current applications with 2000 A AC + DC True RMS, 1400 A AC, and 2000 A DC
- The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
- CAT IV 600 V, CAT III 1000 V rating for added user protection
- In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
- A high voltage measurement of 1000 V AC + DC True RMS, 600 V AC, and 1000 V DC allows the user to perform multiple tests with only one tool
- Resistance to 400K ohms coupled with a continuity beeper provides the convenience of a multimeter in a clamp meter.
- Accurately measure frequency up to 1 kHz for optimum troubleshooting
- Quickly analyze readings using the MIN, MAX, and AVG functions
- A large backlit display allows for easy visibility in low-lit areas
- Use the display hold feature to capture readings even when the display cannot be viewed
- Use the low-pass filter to smooth out noisy loads and stabilize readings
Specifications
Specifications: Fluke 355 True RMS 2000 A Clamp Meter
| Electrical Specifications | ||
| Current measurement DC and AC 10 Hz to 100 Hz | Range | 40 A / 400 A / 2000 A / 1400 AC rms |
| Resolution | 10 mA / 100 mA / 1 A | |
| Accuracy | A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits |
|
| Trigger level for Inrush | 0.50 A / 5.0 A / 5 A | |
| Trigger level for Hz filter OFF | 2.50 A / 2.5 A / 8 A | |
| Trigger level for Hz filter ON | 0.50 A / 2.5 A / 8 A | |
| Crest Factor (50/60 Hz) | Range | 40 A / 400 A / 2000 A / 1400 AC rms |
| Crest Factor1 | 2 @ 33 A, 2.4 @ 27 A 2 @ 330 A, 2.4 @ 270 A 2 @ 1000 A, 2.4 @ 833 A |
|
| Current measurement AC 100.1 Hz to 1 kHz | Range | 40 A / 400 A / 2000 A; 1400 AC rms |
| Resolution | 10 mA / 100 mA / 1 A | |
| Accuracy | 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits |
|
| Trigger level for Inrush | 0.50 A / 5.0 A / 5 A | |
| Trigger level for Hz filter OFF | 2.50 A / 2.5 A / 8 A | |
| Trigger level for Hz filter ON | 0.50 A / 2.5 A / 8 A | |
| Voltage measurement DC and AC 10 Hz to 100 Hz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) |
Range | 4 V / 40 V / 400 V / 600 V AC rms / 1000 VDC |
| Resolution | 1 mV / 10 mV / 100 mV / 1 V | |
| Accuracy | 1% rdg + 10 digits 1% rdg + 5 digits |
|
| Trigger level for Hz filter OFF | 0.25 V / 6 V | |
| Trigger level for Hz filter ON | 0.25 V / 6 V | |
| Voltage measurement AC 100.1 Hz to 1 kHz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) |
Range | 4 V / 40 V / 400 V / 600 V ac rms |
| Resolution | 1 mV / 10 mV / 100 mV / 1 V | |
| Accuracy | 3% rdg + 10 digits 3% rdg + 5 digits |
|
| Trigger level for Hz filter OFF | 0.050 V / 0.25 V / 6 V | |
| Trigger level for Hz filter ON | 0.050 V / 0.25 V / 6 V | |
| Ohms measurement | Range | 4 kΩ / 40 kΩ / 400 kΩ |
| Resolution | 0.1 Ω / 1 Ω / 10 Ω / 100 Ω | |
| Accuracy | 1.5% + 5 digits | |
| Continuity beeper | On at ≤ 30 Ω Off at ≥ 100 Ω |
|
| Frequency measurement | Measurement range | 5.0 Hz to 1 kHz |
| Resolution | 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) | |
| Accuracy – 5.0 Hz to 100 Hz | 0.2% + 2 counts | |
| Accuracy – 100.1 Hz to 1 kHz | 0.5% + 5 counts | |
| Trigger level | Refer to current and voltage tables | |
| 1. Add 2% to error spec for CF > 2 | ||
| General Specifications | ||
| Batteries | Six 1.5 V AA NEDA 15 A or IEC LR6 | |
| Battery life (with typical usage, backlight off) | 100 hours | |
| Test leads | Rated to 1000 V | |
| Weight | .814 kg (1.8 lb) | |
| Jaw size | 58 mm (2.28 in) | |
| Dimensions (L x W x D) | 300 x 98 x 52 mm (12 x 3.75 x 2 in) | |
| Safety rating | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III | |
| Environmental Specifications | ||
| Operating temperature | 32°F to +122°F (0°C to +50°C) | |
| Storage temperature | -4°F to 140°F (-20°C to +60°C) | |
| Operating humidity | 0 to 95% (non-condensing) | |
| Operating altitude | 2000 m | |
| Storage altitude | 10,000 m | |
| IP rating | 42 (indoor use only) | |
| Drop test requirements | 1 m | |
| EMI, RFI, EMC | FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3 V/m, performance criteria B, EN61325 |
|
| Temperature coefficients | Current | 0.1% of reading per °C outside 22°C to 24°C |
| Voltage | 0.1% of reading per °C outside 22°C to 24°C | |
Specifications: Fluke 355 True RMS 2000 A Clamp Meter
| Electrical Specifications | ||
| Current measurement DC and AC 10 Hz to 100 Hz | Range | 40 A / 400 A / 2000 A / 1400 AC rms |
| Resolution | 10 mA / 100 mA / 1 A | |
| Accuracy | A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits |
|
| Trigger level for Inrush | 0.50 A / 5.0 A / 5 A | |
| Trigger level for Hz filter OFF | 2.50 A / 2.5 A / 8 A | |
| Trigger level for Hz filter ON | 0.50 A / 2.5 A / 8 A | |
| Crest Factor (50/60 Hz) | Range | 40 A / 400 A / 2000 A / 1400 AC rms |
| Crest Factor1 | 2 @ 33 A, 2.4 @ 27 A 2 @ 330 A, 2.4 @ 270 A 2 @ 1000 A, 2.4 @ 833 A |
|
| Current measurement AC 100.1 Hz to 1 kHz | Range | 40 A / 400 A / 2000 A; 1400 AC rms |
| Resolution | 10 mA / 100 mA / 1 A | |
| Accuracy | 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits |
|
| Trigger level for Inrush | 0.50 A / 5.0 A / 5 A | |
| Trigger level for Hz filter OFF | 2.50 A / 2.5 A / 8 A | |
| Trigger level for Hz filter ON | 0.50 A / 2.5 A / 8 A | |
| Voltage measurement DC and AC 10 Hz to 100 Hz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) |
Range | 4 V / 40 V / 400 V / 600 V AC rms / 1000 VDC |
| Resolution | 1 mV / 10 mV / 100 mV / 1 V | |
| Accuracy | 1% rdg + 10 digits 1% rdg + 5 digits |
|
| Trigger level for Hz filter OFF | 0.25 V / 6 V | |
| Trigger level for Hz filter ON | 0.25 V / 6 V | |
| Voltage measurement AC 100.1 Hz | ||