Fluke 376 FC True-RMS Clamp Meter
Advanced Wireless True RMS Clamp Meter for Industrial Precision Testing
Product Overview
Fluke 376 FC True-RMS Clamp Meter Price in Bangladesh
Fluke 376 FC True-RMS Clamp Meter is a professional grade electrical testing solution providing tools that you can explore this Clamp Meter Price in Bangladesh and experience advanced measurement accuracy wireless connectivity and high performance industrial diagnostics designed for electricians and engineers.
Fluke 376 FC True-RMS Clamp Meter Price in Bangladesh is built with True RMS technology which ensures accurate readings even when measuring complex or non linear electrical signals. This makes it highly suitable for modern industrial environments where variable speed drives electronic loads and distorted waveforms are common. It delivers stable and reliable results for critical electrical analysis and troubleshooting tasks.
This Clamp Meter Price in Bangladesh supports a wide range of measurement functions including AC DC current voltage resistance frequency and capacitance measurement. It also includes inrush current measurement which helps capture motor startup currents accurately making it ideal for industrial maintenance and equipment diagnostics. The device supports up to 1000A current measurement and can extend to 2500A using the iFlex flexible probe.
One of the most powerful features of the Fluke 376 FC is its wireless connectivity through Fluke Connect. This allows users to remotely log trend and monitor electrical measurements from a safe distance reducing exposure to high voltage environments. This feature is especially valuable in industrial plants where safety and efficiency are critical.
The device is designed with a rugged and durable structure ensuring long term reliability in harsh working environments. Its ergonomic design and large backlit display make it easy to operate and read measurements even in low light conditions. The clamp meter is also equipped with CAT III and CAT IV safety ratings providing high level protection during electrical testing.
Overall the Fluke 376 FC True-RMS Clamp Meter Price in Bangladesh represents a premium industrial tool that combines accuracy safety and smart connectivity. It is widely used in factories power systems and electrical maintenance applications where reliable performance and advanced diagnostic capability are essential.
Key Features: Fluke 376 FC True-RMS Clamp Meter
- Measures AC/DC current with included iFlex current probe
- VFD low pass filter for accurate measurements of non-linear signals
- Remotely log, trend and monitor to pinpoint intermittent faults
- Inrush measurement to filter out noise and capture starting current
Specifications
Specifications: Fluke 376 FC True-RMS Clamp Meter with iFlex
| General Specifications | ||
| AC Current via Jaw | ||
| Range | 999.9 A | |
| Resolution | 0.1 A | |
| Accuracy | 2% ±5 digits (10 Hz to 100 Hz) | |
| 2.5% ±5 digits (100-500 Hz) | ||
| Crest Factor (50 Hz/60 Hz) | 3 @ 500 A | |
| 2.5 @ 600 A | ||
| Add 2% for C.F. >2 | ||
| AC Current via Flexible Current Probe | ||
| Range | 2500 A | |
| Resolution | 0.1 A (≤ 600 A) | |
| 1 A (≤ 2500 A) | ||
| Accuracy | 3% ±5 digits (5 – 500 Hz) | |
| Crest Factor (50/60Hz) | 3.0 at 1100 A | |
| 2.5 at 1400 A | ||
| 1.42 at 2500 A | ||
| Add 2% for C.F. > 2 | ||
| Position Sensitivity | ||
![]() |
||
| i2500-10 Flex | i2500-18 Flex | |
| A | ||
| Distance from Optimum | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) |
| Error | ±0.5 % | ±0.5 % |
| B | ||
| Distance from Optimum | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) |
| Error | ±1.0 % | ±1.0 % |
| C | ||
| Distance from Optimum | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) |
| Error | ±2.0 % | ±2.0 % |
| Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | ||
| DC Current | ||
| Range | 999.9 A | |
| Resolution | 0.1 A | |
| Accuracy | 2% ±5 digits | |
| AC Voltage | ||
| Range | 1000 V | |
| Resolution | 0.1 V (≤600.0 V) | |
| 1 V (≤1000 V) | ||
| Accuracy | 1% ±5 digits (20 Hz to 500 Hz) | |
| DC Voltage | ||
| Range | 1000 V | |
| Resolution | 0.1 V (≤600.0 V) | |
| 1 V (≤1000 V) | ||
| Accuracy | 1% ±5 digits | |
| mV dc | ||
| Range | 500.0 mV | |
| Resolution | 0.1 mV | |
| Accuracy | 1% ±5 digits | |
| Frequency via Jaw | ||
| Range | 5.0 Hz to 500.0 Hz | |
| Resolution | 0.1 Hz | |
| Accuracy | 0.5% ±5 digits | |
| Trigger level | 5 Hz to 10 Hz, ≥10 A | |
| 10 Hz to 100 Hz, ≥5 A | ||
| 100 Hz to 500 Hz, ≥10 A | ||
| Frequency via Flexible Current Probe | ||
| Range | 5.0 Hz to 500.0 Hz | |
| Resolution | 0.1 Hz | |
| Accuracy | 0.5% ±5 digits | |
| Trigger level | 5 Hz to 20 Hz, ≥25 A | |
| 20 Hz to 100 Hz, ≥20 A | ||
| 100 Hz to 500 Hz, ≥25 A | ||
| Resistance | ||
| Range | 60 kΩ | |
| Resolution | 0.1 Ω (≤600 Ω) | |
| 1 Ω (≤6000 Ω) | ||
| 10 Ω (≤60 kΩ) | ||
| Accuracy | 1% ±5 digits | |
| Capacitance | ||
| Range | 1000 μF | |
| Resolution | 0.1 μF (≤ 100 μF) | |
| 1 μ F (≤ 1000 μF) | ||
| Accuracy | 1% ±4 digits | |
| Mechanical Specifications | ||
| Maximum voltage between any terminal and earth ground | 1000 V | |
| Batteries | 2 AA, NEDA 15A, IEC LR6 | |
| Operating temperature | -10 °C to +50 °C | |
| Storage temperature | -40 °C to +60 °C | |
| Operating humidity - non-condensing (< 10°C) |
≤90% RH (at 10 °C to 30 °C) | |
| ≤75% RH (at 30 °C to 40 °C) | ||
| ≤45% RH (at 40 °C to 50 °C) | ||
| Operating altitude | 2000 m | |
| Storage altitude | 12,000 m | |
| Size (L x W x H) | 249 x 85 x 45 mm | |
| Weight | 395 g | |
| Jaw opening | 34 mm | |
| Flexible current probe diameter | 7.5 mm | |
| Flexible current probe cable length (head to electronics connector) |
1.8 m | |
| Safety | IEC 61010-1, Pollution Degree 2 | |
| IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V | ||
| IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V | ||
| IP rating | IEC 60529: IP30, non-operating | |
| Radio Frequency Certification FCC ID& amp; amp; amp; lt; /td> | T68-FBLE IC:6627A-FBLE | |
| Electromagnetic Compatibility (EMC) | ||
| International | IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 | |
| CISPR 11: Group 1, Class A | ||
| Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. | ||
| Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. | ||
| Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) | |
| Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. | ||
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | |
| Temperature coefficients | Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C | |