Fluke 368 FC Leakage Current Clamp Meter

Fluke 368 FC Leakage Current Clamp Meter

Fluke 368 FC Leakage Current Clamp Meter

Advanced Leakage Current Clamp Meter for Precision and Preventive Maintenance

Product Overview

Fluke 368 FC Leakage Current Clamp Meter Price in Bangladesh

Fluke 368 FC Leakage Current Clamp Meter is a professional grade electrical testing solution providing tools that you can explore this Clamp Meter Price in Bangladesh and experience highly accurate leakage current measurement designed for industrial safety and preventive maintenance.

Fluke 368 FC Leakage Current Clamp Meter Price in Bangladesh is specially engineered to detect very small leakage currents with high precision. It offers measurement capability down to microamp levels and up to 60A which makes it ideal for identifying insulation faults leakage issues and unwanted current flow in electrical systems. This allows professionals to detect problems early and prevent unexpected equipment failure or downtime.

This Clamp Meter Price in Bangladesh features True RMS technology which ensures accurate readings even in complex non linear electrical environments. The device includes a fully shielded clamp jaw that minimizes external electromagnetic interference allowing precise detection of very small leakage signals in crowded electrical systems.

One of the key advantages of the Fluke 368 FC is its ability to measure leakage current without disconnecting circuits. This helps reduce downtime and improves efficiency in industrial maintenance tasks. It is widely used in power distribution systems factories and commercial installations where continuous operation is critical.

The device also supports wireless connectivity through Fluke Connect which allows users to monitor record and analyze measurement data over time. This helps technicians track leakage trends and identify potential issues before they turn into major failures.

Fluke 368 FC Leakage Current Clamp Meter is designed with a large 40 mm jaw opening making it suitable for measuring thick conductors and multiple cables. It also includes features like MIN MAX AVG recording backlit display and LED worklight which enhance usability in real world working environments.

Durability and safety are key strengths of this model. It is built according to international safety standards including CAT III 600V ensuring secure operation in industrial electrical systems. Its rugged design ensures long term reliability even in demanding conditions.

Overall the Fluke 368 FC Leakage Current Clamp Meter Price in Bangladesh represents a high end solution for professionals who need precise leakage current detection advanced diagnostics and reliable performance. It is an essential tool for maintaining electrical safety improving system efficiency and preventing costly downtime in modern industrial environments.

Key Features: Fluke 368 FC Leakage Current Clamp Meter

  • Backlit display; auto backlight off and auto power off for extended battery life
  • True-rms measurements for accuracy when measuring complex, non-sinusoidal waveforms
  • 40 mm jaw opening
  • Selectable filter function removes unwanted noise
  • Highest resolution of 1 μA, measure up to 60 A
  • Max/Min/Average readings and hold function
  • Forward-facing LED work light for use in dark wiring cabinets
  • CAT III 600V safety rating
  • Internal Memory Logging: up to 65,000 measurement points
Specifications

Specifications: Fluke 368 FC Leakage Current Clamp Meter

Electrical Specifications
Measurement function Alternating current
AC ampere range 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A
  mA / A: manual selection
3 mA / 30 mA / 300 mA: automatic selection
3 A / 30 A / 60 A: automatic selection
Range / Resolution mA¹ / 0.001 mA
30 mA / 0.01 mA
300 mA / 0.1 mA
3 A / 0.001 A
30 A / 0.01 A
60 A / 0.1 A
Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)² 3 mA – 30 A
60 A
1% + 5 digits
2% + 5 digits
Frequency 40 Hz to 1 kHz
Crest Factor 3
After calibration accuracy is valid for one year. Accuracy is expressed as ± (% of reading + digits). Reference conditions 23 ±5 °C and a maximum relative humidity of 80%.
¹The minimum value is 10 μA rms.
²Outside of the TC / °C 18 °C to 28 °C, 0.02 + 1
Physical
Display (LCD) Digital readout: 3300 count
Display refresh rate 4 times / sec
Maximum conductor diameter 40 mm
Dimensions 234 x 101 x 46 mm
Weight 500 g
Battery 2 AA, IEC LR6, NEDA 15A, alkaline
Battery life Expected battery life, without using backlight and spotlight, is more than 150 hours
Automatic shut-down Meter automatically shuts down after 15 minutes of inactivity
Safety and Environmental Specifications
General safety IEC 61010-1: Pollution Degree 2
Measurement safety IEC 61010-2-032: CAT III 600 V / CAT IV 300 V
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity Non-condensing (<10 °C)
90% relative humidity (10 °C to 30 °C)
75% relative humidity (30 °C to 40 °C)
45% relative humidity (40 °C to 50 °C)
Protection class IEC 60529: IP30 (jaw closed)
Operating altitude 2000 m
Storage altitude 12000 m
Current sensor action category IEC 61557-13: Class 2, ≤30 A / m
Electromagnetic compatibility (EMC)
International
IEC 61326-1 Industrial Electromagnetic Environment
CISPR 11 Group 1 Class B
Group 1 Generated inside the equipment and / or use radio frequency energy associated with conducting the energy for the device's own internal functions is essential.
Class B Equipment for home appliances and residential buildings directly connected to a low voltage power supply network equipment. When this device is connected to a test object, it may exceed the emission levels produced by CISPR 11 requirements.
Korea (KCC): A type of equipment (radio and communication equipment industry)
Class A This product meets the requirements of industrial electromagnetic equipment, vendors or users should be aware of this. This device is intended for use in a commercial environment, instead of the home environment.
USA (FCC): 47 CFR 15 B Subpart. In accordance with section 15.103 provides that the products are considered tax-free device.

Fluke 368 FC Leakage Current Clamp Meter

< td colspan="2">IEC 61010-2-032: CAT III 600 V / CAT IV 300 V
Electrical Specifications
Measurement function Alternating current
AC ampere range 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A
  mA / A: manual selection
3 mA / 30 mA / 300 mA: automatic selection
3 A / 30 A / 60 A: automatic selection
Range / Resolution mA¹ / 0.001 mA
30 mA / 0.01 mA
300 mA / 0.1 mA
3 A / 0.001 A
30 A / 0.01 A
60 A / 0.1 A
Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)² 3 mA – 30 A
60 A
1% + 5 digits
2% + 5 digits
Frequency 40 Hz to 1 kHz
Crest Factor 3
After calibration accuracy is valid for one year. Accuracy is expressed as ± (% of reading + digits). Reference conditions 23 ±5 °C and a maximum relative humidity of 80%.
¹The minimum value is 10 μA rms.
²Outside of the TC / °C 18 °C to 28 °C, 0.02 + 1
Physical
Display (LCD) Digital readout: 3300 count
Display refresh rate 4 times / sec
Maximum conductor diameter 40 mm
Dimensions 234 x 101 x 46 mm
Weight 500 g
Battery 2 AA, IEC LR6, NEDA 15A, alkaline
Battery life Expected battery life, without using backlight and spotlight, is more than 150 hours
Automatic shut-down Meter automatically shuts down after 15 minutes of inactivity
Safety and Environmental Specifications
General safety IEC 61010-1: Pollution Degree 2
Measurement safety
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity Non-condensing (<10 °C)
90% relative humidity (10 °C to 30 °C)
75% relative humidity (30 °C to 40 °C)
45% relative humidity (40 °C to 50 °C)
Protection class

Interested in this product?

Contact us via WhatsApp for more information, pricing, or to place an order.

Contact Us on WhatsApp
WhatsApp Chat