Fluke 375 True RMS AC-DC Clamp Meter

Fluke 375 True RMS AC-DC Clamp Meter

Fluke 375 True RMS AC-DC Clamp Meter

High Performance True RMS Clamp Meter for Advanced Electrical Diagnostics

Product Overview

Fluke 375 True RMS AC-DC Clamp Meter Price in Bangladesh

Fluke 375 True RMS AC-DC Clamp Meter is a professional grade electrical testing solution providing tools that you can explore this Clamp Meter Price in Bangladesh and experience advanced accuracy reliable performance and smart diagnostic capability for industrial and commercial applications.

Fluke 375 True RMS AC-DC Clamp Meter Price in Bangladesh is designed to deliver precise AC and DC current measurement up to 600A along with voltage measurement up to 1000V making it suitable for a wide range of electrical testing environments. With True RMS technology it ensures accurate readings even in non linear electrical systems where waveform distortion is common.

This Clamp Meter Price in Bangladesh also supports extended current measurement up to 2500A when used with an optional flexible iFlex probe allowing technicians to measure large conductors and high current systems with ease. This feature makes it highly effective for industrial power systems heavy equipment and complex electrical installations.

Fluke 375 is equipped with advanced features such as a VFD low pass filter which helps provide accurate motor drive measurements and stable readings in noisy electrical environments. It also includes inrush current measurement which is essential for analyzing motor startup performance and identifying electrical faults in industrial systems.

The device offers a wide range of measurement functions including AC DC voltage resistance capacitance frequency and continuity testing making it a complete diagnostic tool for electricians engineers and maintenance professionals. Its large backlit display ensures clear visibility in low light conditions while the ergonomic design allows comfortable use during long working hours.

Fluke 375 True RMS AC-DC Clamp Meter is built with a rugged and durable structure ensuring long term performance in harsh industrial environments. It also meets high safety standards including CAT III 1000V and CAT IV 600V providing secure operation during high voltage testing and critical electrical work.

Another key advantage of this clamp meter is its compatibility with wireless connectivity in advanced versions allowing users to monitor measurements remotely and improve work efficiency and safety in hazardous environments.

Overall the Fluke 375 True RMS AC-DC Clamp Meter Price in Bangladesh represents a powerful combination of precision durability and advanced functionality. It is an ideal choice for professionals who need a reliable and high performance clamp meter for modern electrical testing and industrial diagnostics in Bangladesh.

Features: Fluke 375 True RMS AC/DC Clamp Meter

  • iFlex flexible current probe expands the measurement range to 2500 A AC while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access.
  • CAT IV 600 V, CAT III 1000 V
  • Ergonomic design fits in your hand and can be used while wearing protective equipment
  • Three-year warranty
  • True RMS AC voltage and current for accurate measurements on non-linear signals
  • 500 mV DC measurement range to interface with other accessories
  • Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environments while providing stable readings
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
  • Soft carrying case
Specifications

Specifications: Fluke 375 True RMS AC/DC Clamp Meter

Electrical Specifications
AC Current via Jaw
Range 374 and 375
376
600.0 A
999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits (10-100 Hz)
2.5% ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz) 3 @ 500 A (375 and 376 only)
2.5 @ 600 A
1.42 @1000 A (376 only)
Add 2% for C.F. > 2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 374 and 375 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
376 0.1 A (≤ 999.9 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A (375 and 376 only)
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Distance from Optimum i2500-10 Flex i2500-18 Flex Error
Flexible current probe A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5%
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0%
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0%
Measurement uncertainty assumes centralized primary conductor at the optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 374 and 375
376
600.0 A
999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits
AC Voltage
Range 374 and 375
376
600.0 V
1000 V
Resolution 374 and 375
376
0.1 V
0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1.5% ± 5 digits (20 – 500 Hz)
DC Voltage
Range 374 and 375
376
600.0 V
1000 V
Resolution 374 and 375
376
0.1 V
0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1% ± 5 digits
mV dc
Range 375 and 376 500.0 mV
Resolution 0.1 mV
Accuracy 1% ± 5 digits
Frequency via Jaw
Range 375 and 376 5.0 - 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 10 Hz, ≥10 A
10 – 100 Hz, ≥5 A
100 – 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range 375 and 376 5.0 - 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 20 Hz, ≥ 25 A
20 – 100 Hz, ≥ 20 A
100 – 500 Hz, ≥ 25 A
Resistance
Range 374
375 and 376
6000 Ω
60 kΩ
Resolution 374 0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
375 and 376 0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
10 Ω (≤ 60 kΩ)
Accuracy 1% ± 5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ± 4 digits
Mechanical Specifications
Size (L x W x H) 246 mm x 83 m x 43 mm
Weight 388 g
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)
1.8 m
Environmental Specifications
Operating Temperature 10°C – +50°C
Storage Temp -40°C – +60°C
Operating Humidity Non condensing (< 10 –°C)
≤ 90% RH (at 10°C – 30°C)
≤ 75% RH (at 30°C – 40°C)
≤ 45% RH (at 40°C – 50°C)
Operating Altitude 3000 meters
Storage Altit ude 12,000 meters
EMC EN 61326-1:2006
Temperature Coefficients Add 0.1 x specified accuracy for each
degree C above 28°C or below 18°C
Safety Specifications
Safety Compliance CAN/CSA-C22.2 No. 61010-1-04
ANSI/UL 61010-1:2004
ANSI/ISA-61010-1 (82.02.01):200 4
EN/IEC 61010-1:2001 to
1000V Measurement Category (CAT) III
600V Measurement Category (CAT) IV
Pollution Degree 2
EN/IEC 61010-2-032:2002
EN/IEC 61010-031:2002+A1:2008
Agency Approvals  
Batteries 2 AA, NEDA 15A, IEC LR6

Specifications: Fluke 375 True RMS AC/DC Clamp Meter

Electrical Specifications
AC Current via Jaw
Range 374 and 375
376
600.0 A
999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits (10-100 Hz)
2.5% ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz) 3 @ 500 A (375 and 376 only)
2.5 @ 600 A
1.42 @1000 A (376 only)
Add 2% for C.F. > 2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 374 and 375 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
376 0.1 A (≤ 999.9 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A (375 and 376 only)
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Distance from Optimum i2500-10 Flex i2500-18 Flex Error
Flexible current probe A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5%
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0%
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0%
Measurement uncertainty assumes centralized primary conductor at the optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 374 and 375
376
600.0 A
999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits
AC Voltage
Range 374 and 375
376
600.0 V
1000 V
Resolution 374 and 375
376
0.1 V
0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1.5% ± 5 digits (20 – 500 Hz)
DC Voltage
Range 374 and 375
376
600.0 V
1000 V
Resolution 374 and 375
376
0.1 V
0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1% ± 5 digits
mV dc
Range 375 and 376 500.0 mV
Resolution 0.1 mV
Accuracy 1% ± 5 digits
Frequency via Jaw
Range 375 and 376 5.0 - 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 10 Hz, ≥10 A
10 – 100 Hz, ≥5 A
100 – 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range 375 and 376 5.0 - 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 20 Hz, ≥ 25 A
20 – 100 Hz, ≥ 20 A
100 – 500 Hz, ≥ 25 A
Resistance
Range 374
375 and 376
6000 Ω
60 kΩ
Resolution 374 0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
375 and 376 0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
10 Ω (≤ 60 kΩ)
Accuracy 1% ± 5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ± 4 digits
Mechanical Specifications
Size (L x W x H) 246 mm x 83 m x 43 mm
Weight 388 g
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)
1.8 m
Environmental Specifications
Operating Temperature 10°C – +50°C
Storage Temp -40°C – +60°C
Operating Humidity Non condensing (< 10 –°C)
≤ 90% RH (at 10°C – 30°C)
≤ 75% RH (at 30°C – 40°C)
≤ 45% RH (at 40°C – 50°C)
Operating Altitude 3000 meters
Storage Altitude 12,000 meters
EMC EN 61

Interested in this product?

Contact us via WhatsApp for more information, pricing, or to place an order.

Contact Us on WhatsApp
WhatsApp Chat