Kyoritsu 6516BT Digital Multifunction Installation Tester
All in one solution for advanced electrical testing
Product Overview
Kyoritsu 6516BT Digital Multifunction Installation Tester Price in Bangladesh
Kyoritsu 6516BT Digital Multifunction Installation Tester is a powerful and versatile testing instrument, and the Kyoritsu 6516BT Digital Multifunction Installation Tester Price in Bangladesh is often searched by professionals who need a complete solution for electrical installation testing. Designed for efficiency and accuracy, this device combines multiple testing functions into a single compact unit, making it highly suitable for modern electrical work.
Engineered with advanced multifunction capabilities, the tester can perform insulation resistance, continuity, loop impedance, RCD testing, earth resistance, and voltage measurement without the need for separate devices. This all in one functionality significantly improves workflow efficiency and reduces the need to carry multiple instruments on site. It is especially useful for professionals working in industrial, commercial, and installation environments.
The device features a clear color LCD display that enhances visibility and allows users to easily interpret test results. Its intuitive interface guides users through different testing modes, reducing operational complexity and minimizing the risk of incorrect connections. This makes it suitable for both experienced engineers and technicians who require reliable and fast testing performance.
One of the standout features of this tester is its advanced Anti Trip Technology, which enables loop impedance testing without tripping RCDs. This ensures smooth and uninterrupted testing, particularly in sensitive electrical systems. Additionally, the device supports various RCD types and testing modes, allowing comprehensive evaluation of safety systems in electrical installations.
Smart connectivity further enhances its usability. With built in Bluetooth functionality, users can transfer data wirelessly to compatible devices for analysis and reporting. This helps streamline documentation processes and reduces manual recording errors, making it ideal for professionals who prioritize efficiency and accuracy in their work.
Durability is another key strength of this model. Built with a rugged and impact resistant design, it is capable of withstanding tough working conditions commonly found in construction sites and industrial environments. Its ergonomic structure ensures comfortable handling during extended use, while maintaining consistent performance over time.
Safety remains a core focus in its design, with features such as automatic discharge, clear connection guidance, and compliance with international safety standards. These elements help protect both the user and the equipment during operation, ensuring dependable performance in critical applications.
Overall, this multifunction installation tester stands out for its comprehensive testing capabilities, smart features, and durable construction. It is an essential tool for professionals who require accurate, efficient, and reliable electrical testing in a wide range of applications.
Key Features: Kyoritsu 6516BT Digital Multifunction Installation Tester
- DISPLAY
Color LCD 3.5 inches dot matrix. - ATT
Anti-Trip Technology (with 2 & 3 wire) for no trip LOOP L-PE testing on all RCDs.
With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines). - LOOP
・High test current range of 2Ω with 0.001Ω resolution.
・Zs Limit compares the values required by Electrical Installations Standard with measured results. - RCD
・Type AC, A, F, B(General & Selective), EV and Variable RCDs.
・Single and Auto test, Ramp test and Contact voltage. - EARTH
Earth resistance test 2 and 3 wires with all accessories included. - INSULATION
Resistance test 100, 250, 500 & 1000V with auto discharge voltage. - CONTINUITY
Continuity test at 200mA or 15mA with selectable buzzer for fast judgment. - PHASE ROTATION
On 3-phase lines with clear indication of the sequence on the display. - VOLTS
TRMS Voltage measurements 2-600V, Mains Frequency. - HELP
Display shows how to connect the instrument according to the function selected. - SPD
Surge Protection Device test, for SPD that uses varistor. - PAT
Portable Appliance Tester function, for Insulation and Protective conductor resistance test - Bluetooth
Communication by "KEW CONNECT" - SAFETY
IEC 61010-1 CAT Ⅳ 300V / CAT Ⅲ 600V, IEC 61557-1,2,3,4,5,6,7,10.
Specifications
Specifications: Kyoritsu 6516BT Digital Multifunction Installation Tester
| Insulation resistance | SPD (Varistor) |
||||||
|---|---|---|---|---|---|---|---|
| Test voltage | 100V | 250V | 500V | 1000V | Max.1000V | ||
| Measuring ranges | 2.000/20.00/200.0MΩ (Auto-ranging) |
20.00/200.0/ 1000MΩ (Auto-ranging) |
20.00/200.0/ 2000MΩ (Auto-ranging) |
0-1049V (goes up by 1V) |
|||
| Accuracy | ±2%rdg±6dgt (2.000/20.00MΩ) ±5%rdg±6dgt (200.0MΩ) |
±2%rdg±6dgt (20.00/200.0MΩ) ±5%rdg±6dgt (1000MΩ) |
±2%rdg±6dgt (20.00/200.0MΩ) ±5%rdg±6dgt (2000MΩ) |
±5%rdg±5dgt | |||
| Rated current | 1.0-1.2mA @0.1MΩ |
1.0-1.2mA @0.25MΩ |
1.0-1.2mA @0.5MΩ |
1.0-1.2mA @1MΩ |
‐ | ||
| Output short circuit current | 1.5mA max | ‐ | |||||
| Loop impedance | |||||||
| Function | LOOP ATT | LOOP HIGH | |||||
| L-PE/L-N (3wire) |
L-PE (2wire) |
L-PE (0.01ΩRes) |
L-PE (0.001ΩRes) High test current (25A) |
L-N/L-L | |||
| Rated voltage | 100-260V (50/60Hz) |
48-260V (50/60Hz) |
48-260V (50/60Hz) |
100-260V (50/60Hz) |
48-500V (50/60Hz) |
||
| Impedance range | 20.00/200.0/2000Ω (Auto-ranging) |
20.00/200.0/2000Ω (Auto-ranging) |
2.000Ω | 20.00Ω | |||
| Accuracy | ±3%rdg±6dgt | ±3%rdg±10dgt | ±3%rdg±4dgt | ±3%rdg±25mΩ | ±3%rdg±4dgt | ||
| Nominal test current at 0Ω external loop: Magnitude/ Duration at 230V |
L-N:6A/60ms N-PE:10mA |
L-PE:15mA | 20Ω: 6A/20ms 200Ω: 0.5A/20ms 2000Ω: 15mA/500ms |
25A/20ms | 6A/20ms | ||
| PSC/PFC | |||||||
| Range | 2000A/20kA (L-N(PSC)/L-PE(PFC)) |
2000A/20kA (PFC) |
2000A/20kA (PFC) |
2000A/50kA (PFC) |
2000A/20kA (PSC) |
||
| Accuracy | PSC/PFC accuracy is derived from measured loop impedance specification and measured voltage specification | ||||||
| RCD | |||||||
| Rated voltage | 100-260V(50/60Hz) | ||||||
| Function | x1/2, x1,x5,Ramp,Auto,Uc | ||||||
| 6/10/30/100/300/500/1000mA/variable | |||||||
| RCD type | AC(G/S) | A(G/S) | F(G/S) | B(G/S) | EV | ||
| Trip current setting |
x1/2, x1,Uc |
10/30/100/300/ 500/1000mA(G) 10/30/100/ 300/500(S) |
10/30/100/ 300/500mA |
10/30/100/ 300/500mA |
10/30/100/ 300mA |
6mA (x1 only) |
|
| x5 | 10/30/100mA | 10/30/100mA | 10/30/100mA | 10/30mA | - | ||
| Ramp | 10/30/100/ 300/500mA |
10/30/100/ 300/500mA |
10/30/100/ 300/500mA |
10/30/100/ 300mA |
6mA | ||
| Accuracy | Trip current |
x1/2 | -8 - -2% | -10 - 0% | -10 - 0% | -10 - 0% | - |
| x1 | +2 - +8% | 0 - +10% | 0 - +10% | 0 - +10% | 0 - +10% | ||
| x5 | +2 - +8% | 0 - +10% | 0 - +10% | 0 - +10% | - | ||
| Ramp | -4 - +4% | -10 - +10% | -10 - +10% | -10 - +10% | -10 - +10% | ||
| Trip time |
x1/2 | 2000ms(G/S):±1%rdg±2ms | - | ||||
| x1 | 550ms(G):±1%rdg±2ms,1000ms(S):±1%rdg±2ms | 10.5s:±1%±2㎳ | |||||
| x5 | 410ms(G/S):±1%rdg±2ms | - | |||||
| Continuity | |||||||
| Range | 20.00/200.0/2000Ω (Auto-ranging) | ||||||
| Open circuit voltage(DC) | 7-14V | ||||||
| Measuring current |
200mA | 200mA or more(2Ω or less) | |||||
| 15mA | 15mA±3mA(short-circuit) | ||||||
| Accuracy | ±2%rdg±8dgt | ||||||
| Volts | |||||||
| Range | 300.0/600V(Auto-ranging) | ||||||
| Measuring ranges |
Volts | 2-600V | |||||
| Frequency | 45-65Hz | ||||||
| Accuracy | Volts | ±2%rdg±4dgt | |||||
| Frequency | ±0.5%rdg±2dgt | ||||||
| Phase Rotation | |||||||
| Rated voltage | 48-600V(45-65Hz) | ||||||
| Remarks | Remarks Correct phase sequence: are displayed “1.2.3” and mark Reversed phase sequence: are displayed “3.2.1” and mark |
||||||
| Earth | |||||||
| Range | 20.00/200.0/2000Ω(Au to-ranging) | ||||||
| Accuracy | ±2%rdg±0.08Ω(20.00Ω) ±2%rdg±3dgt(200.0/2000Ω) |
||||||
| General | |||||||
| Applicable standards | IEC 61010-1 CAT IV 300V / CAT III 600 V Pollution degree 2 IEC 61010-2-034, IEC 61557-1,2,3,4,5,6,7,10 IEC 60529(IP40), IEC 61326(EMC) |
||||||
| Communication interface | USB, Bluetooth® 5.0 | ||||||
| Power source | LR6 (AA) (1.5V) ×8 | ||||||
| Communication interface | USB | ||||||
| Dimension / Weight | 136(L) × 235(W) × 114(D) mm / 1350g (including batteries) | ||||||
| Accessories | Mains test lead*1 7281 (Test leads with remote control switch) 7246 (Distribution board test lead) 7228A (Earth resistance test leads) 8041 (Auxiliary earth spikes[2 spikes/1 set]) 9084 (Soft case) 9142 (Carrying case) 9151 (Shoulder strap) 9199 (Shoulder pad) LR6(AA) × 8 Instruction manual Calibration certificate |
||||||
| Optional Accessories |
8212-USB (USB adapter) |
||||||